Buildings
Buildings fire strategy review and validation
In higher-risk and commercial buildings, JWCS applies the same fire engineering discipline it applies on the railway: the review of buildings fire strategies and fire documentation prepared by others, and the validation of a completed building's fire strategy. JWCS also offers fire safety documentation for Building Safety Regulator applications, Approved Document B plan checks, golden thread review, and fire risk assessment of commercial and industrial premises.
Fire Strategy Reporting
-
Validation of a completed building's fire strategy
The strategy is checked against the building's as-built and completion evidence.
-
Occupied building fire documentation review
Review of the fire strategy and fire documentation of occupied buildings, including occupied higher-risk residential buildings.
-
Passive fire protection records
Review of passive fire protection records, such as fire door and firestopping inspection records, as part of an independent review of an occupied building's fire documentation.
-
Building Safety Regulator applications
Fire safety documentation for the client's application to the Building Safety Regulator: Gateway 2, Gateway 3 or regularisation. The client is the applicant.
-
Approved Document B plan checks
Fire engineering review of design information against Approved Document B Volume 1 or Volume 2, for designers, clients and building control bodies. Building control decisions rest with the building control body.
-
Golden thread review
Review and gap analysis of a higher-risk building's fire safety information. The golden thread duties stay with the duty-holders.
-
Technical and peer review of buildings fire strategies
Technical and peer review of buildings fire strategies and fire engineering documentation prepared by others.
Fire risk assessment
Fire risk assessment of commercial and industrial premises under the Regulatory Reform (Fire Safety) Order 2005, in line with the method of PAS 79-1:2020. Assessments are non-intrusive; where an assessment finds indicators of concealed defects, it recommends intrusive investigation by a suitably qualified specialist. Where the external wall needs appraisal, the assessment recommends one.
How JWCS acts in this work
Each document under review is read against the code that governs its premises class: BS 9999:2017 and Approved Document B Volume 2 for buildings other than dwellings, BS 9991:2024 and Approved Document B Volume 1 for residential buildings, and BS 9992:2020 for rail premises. The codes are never conflated.
In its review and validation work JWCS acts as an independent reviewer. It does not take a Building Safety Act 2022 higher-risk building duty-holder, Principal Designer or accountable-person competent person role.
JWCS does not review or validate a fire strategy that JWCS authored or issued.
Fire strategy design for buildings other than dwellings is described under Fire Strategy Design.